jwst-gc pipeline monitor

m92 · 2026-09-19 09:35 EDT
1 runs 1 failing 0 flagged 0 clear 0 queued

Overview

One card per registered observation. The bar is the stage ladder in run order — reduction (unc·cal·red·i2d) then cataloging (m12→m8). Solid = every filter has it, pale = some do, STRIPED = it exists but predates an earlier stage, so it was built from inputs that have since been regenerated, hatched = the product name cannot be attributed to this observation. Click a card for the detail.

Cutout runs

Every cutout run on disk: the shared monitor5as probes plus the hand-made experiment cutouts. A cutout run stops after m6 — m7 and m8 need more than one filter — so "catalogs" here counts per-filter products only. These rows also flag zero-byte products and orphan tmp* files: a write that died mid-flight leaves both, and a count-based ladder reads them as finished work.

fieldlabelframescatalogs filterstouchedflags
m92monitor5as 221 F150W:2 48d ago

Detail

m92 · 1334/o001

/orange/adamginsburg/jwst/m92 back to overview

Stage ladder

unccalredi2dm12m3m4m5m6m7m8

Products per filter

filterunccalcrfredi2dsatm12m3m4m5m6reduced as
F090W3232·3260133333destreak
F150W3232·3260133333destreak
F277W88·860133333destreak
F444W88·860133333destreak

* = the product name carries no _o<obs> token and this field has more than one observation, so the count cannot be attributed to 1334/o001.

Astrometry — m2 checkpoint

filtervisitexposuresmisaligned sweptmin contrastbulk tie (mas)tie from tiles okworst tile (mas)cell checkpoint
F090W_o001 1 32 0 0 236 —/— 2026-09-03T19:17:08Z
F150W_o001 1 32 8 0 558 —/— 2026-09-03T19:48:07Z
F277W_o001 1 8 2 0 1025 —/— 2026-09-03T20:18:35Z
F444W_o001 1 8 1 0 921 —/— 2026-09-03T20:33:54Z

“tiles ok” is not a tolerance. measure_offset_grid runs with no max_off_mas, and astrometry_offsets sets off_ok=True whenever that is None — so N/N counts tiles whose offset histogram had a coherent peak, however large the offset. The column that carries the gate is worst tile, against 15 mas.

Provenance

phaseproductspipeline tag(s)
m7152026-09-04_PR677_f404dcc-dirty (15)
m832026-09-04_PR677_f404dcc-dirty (3)

Queue

No jobs in the queue for this field.

Findings

  • fail
    F150W_o001: 8/32 exposures misaligned vs their visit consensus
    An exposure is misaligned when its offset exceeds 2.0 mas AND is significant against the peak error bars. At m2 this CORRECTS the offsets table and stops the run; the crf frames must be regenerated before cataloging continues.
    checkpoint_m2_F150W_o001_latest.json
    what is affected, and why
    Affected: 8/8 detectors — spread across detectors, so the frame as a whole moved: look at the offsets table and whether these exposures were regenerated from _cal after the table changed. fix_alignment SKIPS a frame that already has a RAOFFSET header, so correcting the table alone leaves stale frames in place; regenerate the working copy from _cal instead of re-applying on top.
    nrca1 visit 1: dRA -1.0, dDec -2.2 masnrca2 visit 1: dRA -1.0, dDec -2.2 masnrca3 visit 1: dRA -1.0, dDec -2.2 masnrca4 visit 1: dRA -1.0, dDec -2.2 masnrcb1 visit 1: dRA -1.0, dDec -2.2 masnrcb2 visit 1: dRA -1.0, dDec -2.2 masnrcb3 visit 1: dRA -1.0, dDec -2.2 masnrcb4 visit 1: dRA -1.0, dDec -2.3 masnrca1 nrca2 nrca3 nrca4 nrcb1 nrcb2 nrcb3 nrcb4±2 mas
    Per-exposure offset vectors, coloured by detector. Solid = flagged misaligned. One colour pointing away means one detector; everything fanning out means the frame moved.
    Misaligned by detector
    nrca11/4
    nrca21/4
    nrca31/4
    nrca41/4
    nrcb11/4
    nrcb21/4
    nrcb31/4
    nrcb41/4
    visitdetectordRA (mas)dDec (mas)off (mas)contrastpairswindow ("")
    1nrca1-1.0-2.22.51,550.32070553.0
    1nrca2-1.0-2.22.41,484.02042363.0
    1nrca3-1.0-2.22.4790.68980213.0
    1nrca4-1.0-2.22.5726.29414703.0
    1nrcb1-1.0-2.22.41,560.02536733.0
    1nrcb2-1.0-2.22.41,224.02736003.0
    1nrcb3-1.0-2.22.4696.210030943.0
    1nrcb4-1.0-2.32.5650.911663653.0
  • fail
    F277W_o001: 2/8 exposures misaligned vs their visit consensus
    An exposure is misaligned when its offset exceeds 2.0 mas AND is significant against the peak error bars. At m2 this CORRECTS the offsets table and stops the run; the crf frames must be regenerated before cataloging continues.
    checkpoint_m2_F277W_o001_latest.json
    what is affected, and why
    Affected: 2/2 detectors — spread across detectors, so the frame as a whole moved: look at the offsets table and whether these exposures were regenerated from _cal after the table changed. fix_alignment SKIPS a frame that already has a RAOFFSET header, so correcting the table alone leaves stale frames in place; regenerate the working copy from _cal instead of re-applying on top.
    nrcalong visit 1: dRA 1.8, dDec -3.1 masnrcblong visit 1: dRA 1.7, dDec -3.1 masnrcalong nrcblong±3 mas
    Per-exposure offset vectors, coloured by detector. Solid = flagged misaligned. One colour pointing away means one detector; everything fanning out means the frame moved.
    Misaligned by detector
    nrcalong1/4
    nrcblong1/4
    visitdetectordRA (mas)dDec (mas)off (mas)contrastpairswindow ("")
    1nrcalong1.8-3.13.61,787.04196943.0
    1nrcblong1.7-3.13.61,905.84847473.0
  • fail
    F444W_o001: 1/8 exposures misaligned vs their visit consensus
    An exposure is misaligned when its offset exceeds 2.0 mas AND is significant against the peak error bars. At m2 this CORRECTS the offsets table and stops the run; the crf frames must be regenerated before cataloging continues.
    checkpoint_m2_F444W_o001_latest.json
    what is affected, and why
    Affected: 1/2 detectors — confined to nrcalong, which points at a detector-local defect (distortion reference, a bad filteroffset, or one chip's frames never re-aligned) rather than a whole-frame misalignment. fix_alignment SKIPS a frame that already has a RAOFFSET header, so correcting the table alone leaves stale frames in place; regenerate the working copy from _cal instead of re-applying on top.
    nrcalong visit 1: dRA -0.9, dDec -1.8 masnrcalong nrcblong±2 mas
    Per-exposure offset vectors, coloured by detector. Solid = flagged misaligned. One colour pointing away means one detector; everything fanning out means the frame moved.
    Misaligned by detector
    nrcalong1/4
    nrcblong0/4
    visitdetectordRA (mas)dDec (mas)off (mas)contrastpairswindow ("")
    1nrcalong-0.9-1.82.02,192.34739903.0
  • warn
    m7: 15 product(s) stamped with a -dirty tag
    The tree had uncommitted changes, so the tag does not identify the code that ran. Fine for a development run; not for a release.
    catalogs/*m7*.prov.json
    what is affected, and why
  • warn
    m8: 3 product(s) stamped with a -dirty tag
    The tree had uncommitted changes, so the tag does not identify the code that ran. Fine for a development run; not for a release.
    catalogs/*m8*.prov.json
    what is affected, and why
  • ok
    F090W_o001: all 32 exposures within 2.0 mas of consensus
    checkpoint_m2_F090W_o001_latest.json
  • ok
    m7 present (3 file(s))
    catalogs/
  • ok
    m8 present (3 file(s))
    catalogs/
  • ok
    8 recent log(s), no error signatures
    logs/
  • ok
    m7: single tag 2026-09-04_PR677_f404dcc-dirty (15 products)
    catalogs/*m7*.prov.json
  • ok
    m8: single tag 2026-09-04_PR677_f404dcc-dirty (3 products)
    catalogs/*m8*.prov.json
Generated 2026-09-19 09:35 EDT. Every number here is read from what the pipeline recorded — the tolerances are the ones the pipeline itself enforces, and no offset is re-measured for this page.